Publicación:
Aplicación para el análisis acústico y auralización de recintos cerrados

dc.audienceComunidad Científica y Académicaspa
dc.contributor.advisorBetancur vargas, Carlos Mauricio
dc.contributor.authorCastaño Melo, Edward Steven
dc.date.accessioned2017-10-18T17:49:31Z
dc.date.available2017-10-18T17:49:31Z
dc.date.issued2017
dc.date.submitted2017-10
dc.description.abstractThis proyect describes an application developed in a graphical environment called MATLAB (GUI), to evaluate acoustics in closed enclosures. This application is conformed by two tools, the first tool allow us to get done an acoustic analysis calculating the parameters of a room staring from the measurenment of the impulse response (RIR); With the second tool it’s possible to make auralizations starting from the dimensions and features of a room. In order to evaluate the quality of this application was compared with commercial softwares in the market, measurements were taken in two rooms with different acoustic characteristicseng
dc.description.abstractEste proyecto, describe una aplicación desarrollada en el entorno grafico de MATLAB (GUI) para valorar la acústica en recintos cerrados. La aplicación está conformada por dos herramientas, la primera nos permite realizar un análisis acústico calculando los parámetros de una sala partiendo de la medición de la respuesta impulsiva (RIR); Con la segunda herramienta se pueden realizar auralizaciones partiendo de las dimensiones y características de una sala. Con el fin de evaluar la calidad de la aplicación se comparó con otros softwares comerciales en el mercado, realizando mediciones en dos recintos con características acústicas diferentes.spa
dc.formatpdfspa
dc.format.extent100 páginasspa
dc.format.mediumRecurso en lineaspa
dc.format.mimetypeapplication/pdfspa
dc.identifier.urihttp://hdl.handle.net/10819/4598
dc.language.isospaspa
dc.publisherUniversidad de San Buenaventuraspa
dc.publisher.facultyIngenieriasspa
dc.publisher.programIngeniería Electrónicaspa
dc.publisher.sedeCalispa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.ccAtribución-NoComercial-SinDerivadas 2.5 Colombiaspa
dc.rights.licenciaPor medio de este formato manifiesto mi voluntad de AUTORIZAR a la Universidad de San Buenaventura, Sede Bogotá, Seccionales Medellín, Cali y Cartagena, la difusión en texto completo de manera gratuita y por tiempo indefinido en la Biblioteca Digital Universidad de San Buenaventura, el documento académico-investigativo objeto de la presente autorización, con fines estrictamente educativos, científicos y culturales, en los términos establecidos en la Ley 23 de 1982, Ley 44 de 1993, Decisión Andina 351 de 1993, Decreto 460 de 1995 y demás normas generales sobre derechos de autor. Como autor manifiesto que el presente documento académico-investigativo es original y se realiza sin violar o usurpar derechos de autor de terceros, por lo tanto, la obra es de mi exclusiva autora y poseo la titularidad sobre la misma. La Universidad de San Buenaventura no será responsable de ninguna utilización indebida del documento por parte de terceros y será exclusivamente mi responsabilidad atender personalmente cualquier reclamación que pueda presentarse a la Universidad. Autorizo a la Biblioteca Digital de la Universidad de San Buenaventura convertir el documento al formato que el repositorio lo requiera (impreso, digital, electrónico o cualquier otro conocido o por conocer) o con fines de preservación digital. Esta autorización no implica renuncia a la facultad que tengo de publicar posteriormente la obra, en forma total o parcial, por lo cual podrá, dando aviso por escrito con no menos de un mes de antelación, solicitar que el documento deje de estar disponible para el público en la Biblioteca Digital de la Universidad de San Buenaventura, así mismo, cuando se requiera por razones legales y/o reglas del editor de una revista.spa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/spa
dc.source.bibliographicCitation[1] M. Vorländer, Auralization, Berlin, 2008. [2] M. A. Saposhkov, «Electroacústica,» 1983. [3] I. 3382, «Medición de parametros acústicos en recintos,» 2008. [4] J. Magro Sastre, Desarrollo de herramientas de procesado y visualización para audio 3D con auriculares., Madrid, 2016. [5] D. E. Cárdenas Uribe y I. F. Correa Galvis, Método de auralización orientado a la implementación de teoría acústica de preferencia subjetiva en salas de concierto, Bogotá, 2011. [6] C. Mesa Villanueva, «Sistema de medición de parametros acústicos en recintos y compensación espectral.,» 2011. [7] K. Ogata, Ingeniería de control moderna, 2010. [8] Billon y Embrechts, Ray-tracing modelling of the diffraction by half-planes and slits based on the energy flow lines concept, Nantes, 2012. [9] S. Tervo, J. Pätynen y T. Lokki, «Acoustic reflection localization from room,» Enero, Febrero 2013. [10] H. Kuttruff, Acoustics: An Introduction., 2007. [11] A. Oppenheim y A. Willsky, Señales y Sistemas, Boston, 1998. [12] F. Ramón, «equaphon-university.net,» 2014. [En línea]. Available: http://www.equaphon-university.net/senales-de-prueba/. [13] M. Vorlander, «Electroacústica Aplicada,» Tebain, 2007, pp. 106,107. [14] H. Kuttruff, «Room Acoustics,» Aachen, 2009. [15] F. C. Tommasini, Sistema de simulación acústica virtual en tiempo real, 2012. [16] A. Yoichi, Architectual acoustics 1ra edition, Springer, 1998. [17] A. Jimenez, Estudio de la evolución de parametros acústicos, Valencia, 2003. [18] K. Arcaya, «El Rincón del Audio y Acústica.,» [En línea]. Available: http://elrincondelaudioylaacustica.blogspot.com.co/2010/04/las-famosas-curvas-nc_19.html. [19] UnAD, «datateca.unad.edu.co,» [En línea]. Available: http://datateca.unad.edu.co/contenidos/208038/ContLin/criterios_psicoacusticos_para_auditorios.html. [20] L. L. Beranek, Concert hall and opera houses, 2003. [21] L. Ojer, «AcústicaFácil,» 2013. [En línea]. Available: http://www.ingenieriaacusticafacil.com/ingenieria-acustica-5-parametros-acusticos-que-debes-conocer/. [22] A. Puchades, ¿Es el criterio acústico el paradigma de la excelencia acústica en el diseño de salas?, 2008. [23] A. Carrion, Diseño acustico de espacios arquitectónicos, 1998. [24] H. Wilkens, Beschreibung subjektiver Beurteilungen der Akustik von Konzertsaelen, Berlin, 1975. [25] A. Marshall, Spatial impression due to early lateral reflections in concert halls, 1981. [26] J. F. Noriega, «Procedure for obtaining impulse response of a room, and their application in multichannel systems,» p. 8, 2014. [27] R. Martín, Influence of the Source Orientation on the Measurement of Acoustic Parameters, 2007. [28] M. Ramirez, «meyersound.com,» 2011. [En línea]. Available: https://meyersound.adobeconnect.com/_a838360253/p8eeh0f1iwk/?launcher=false&fcsContent=true&pbMode=normal. [29] U. d. P. Vasco, «Procesado digital de imagen y sonido,» 2007. [30] M. Henriquez, Evaluación De Auralizaciones Creadas Mediante Métodos Numéricos Basados En Acústica Geométrica Y Reproducidas En El Sistema De Reproducción Binaural Opsodis, 2014. [31] Schroeder, 1974. [32] J. Segura, Análisis de respuestas impulsivas en salas de audición, Leon, 2010. [33] J. F. C. Zuñiga, Modelamiento de espacios acústicos virtuales por medio de trazado de rayos y fuente imagen, Medellin, 2014. [34] E. A. L. y A. M. J. , Prediction of energy decay in room impulse responses simulated with an image-source model, Crawley, 2008.spa
dc.source.instnameUniversidad de San Buenaventura - Calispa
dc.source.otherCali, Trabajo de Grado, T621.3828 C346aspa
dc.source.reponameBiblioteca Digital Universidad de San Buenaventuraspa
dc.subjectMatlabspa
dc.subjectAnálisis acústicospa
dc.subjectAuralización,spa
dc.subjectRespuesta al impulso de un recintospa
dc.subjectAcoustic analysis,spa
dc.subjectAuralisation,spa
dc.subjectRoom impulse responsespa
dc.subject.lembSistema de sonidospa
dc.subject.lembIngeniería acústicaspa
dc.subject.lembMatlab (Lenguaje de programación)spa
dc.thesis.nameIngeniero Electrónicospa
dc.titleAplicación para el análisis acústico y auralización de recintos cerradosspa
dc.typeTrabajo de grado - Pregradospa
dc.type.driverinfo:eu-repo/semantics/bachelorThesisspa
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersionspa
dc.type.spaTrabajo de Gradospa
dspace.entity.typePublicationspa
Archivos
Paquete original
Mostrando 1 - 1 de 1
Imagen en miniatura
Nombre:
Aplicacion_Analisis_Acustico_Castano_2017.pdf
Tamaño:
3.22 MB
Formato:
Adobe Portable Document Format
Descripción:
Paquete de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
2.02 KB
Formato:
Item-specific license agreed upon to submission
Descripción: